uninterruptible power management

Three Phase UPS-GT33300L64

BP 650
Key Features & Application

  • True On Line – Double Conversion Technology
  • Latest Technology Floating Point (DSP) Controllers
  • IGBT PWM rectifier & inverter technology
  • Low input current THD (<%3)
  • High input power factor (>0.99)
  • High efficiency >94%
  • Wide input voltage range 140-280 V (L-N)
  • Dual mains input
  • Advanced battery management
  • Short circuit and overload protection
  • Selectable number of batteries
  • Output frequency configurable (40~80 Hz)
  • Output voltage configurable (180~280 V)
  • 500 event log with detailed parameters record
  • Static & manual bypass operation
  • Easy and free power upgrade
  • Overload and short circuit protection
  • Paralleling function inbuilt
  • Small footprint and easy maintenance
  • Advanced communication capabilities
  • Perfect generator compatibilty
  • Customizable as frequency converter
  • Cold start function
  • Auto Restart function
  • Emergency power off
MODEL  GT33300L64
PHASE 3 Phase IN / 3 Phase OUT
CAPACITY 300KVA
INPUT
Nominal Voltage 3 x 400 VAC (3Ph+N)
Voltage Range  220/380VAC( -15% , +18% 3P + N +PE)
Frequency Range 45~65 Hz (Selectable)
Power Factor ≧ 0.99  @ 100% load
Rectifier IGBT Rectifier
Total Harmonic Distortion (THDI) <3%
OUTPUT
Output Voltage 3 x 400 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode) ± 1%
Frequency Range (Synchronized Range) 50 Hz ± 0.5%,Synchronous with network ,
Frequency Range (Batt. Mode) (50Hz ± 0.2 % Battery Mode)
Current Crest Ratio 3:1 (max.)
Harmonic Distortion ≦ 2 % THD (Linear Load) ,≦ 5 % THD (Non-linear Load)
Transfer Time AC mode to Battery mode zero
Inverter to Bypass zero
Waveform (Batt. Mode) Pure Sine Wave
EFFICIENCY UP to 93%
Overload Capacity At 125% Load 10 min,at 150% load 1 min
Protections The input voltage is out of tolerance, input frequency is out of tolerance, input phase failure, output voltage is out of tolerance, output frequency is out of tolerance, output phase failure, DC component that can occur at the output voltage, overload that will occur at the output (out of the periods specified), overheating that will cause failure related to over temperature, high voltage which will occur at dc bus voltage, low voltage which will occur at dc bus voltage, short circuit at the ouput.
BATTERY
Numbers 12V x64Nos
Typical Recharge Time 9 hours recover to 90% capacity
Charge Value( C ) Nominal 0.1C, Adjustable
Battery Power 25% of the device power
COMMUNICATION
Communication port RS232 Standart, RS485 ve SNMP Adapter option
Dry Contact Optional
Protocol SEC, TELNET
CERTIFICATES
Quality ISO 9001-ISO 14001
Standard EN62040-1-1, IEN60950
EMC/LVD EN62040-2
GENERAL
Running Temperature For UPS 0 ~40°C for Battery 0~ 25°C
Storage Temperature For UPS 15 ~45°C for Battery 10~ 60°C
Protection Class IP20
Chassis Anti-Static Paint Protection
Humidity 0~95%
Altitude <1000m,correction Factor1.<2000m,correction Factor>0.92,<3000m,correction Factor >0.84
Alerts 500 Event Log.(Optional Status Record)
Parallel Operation Parallel Power Increase UP to 16 pcs.
EPO Standard
Isolation Transformer Optional
Net Weight 750 Kg
Dimensions(WxDxH) in mm 1250x805x1905